Made in USA
ISO 9001:2015 Registered
SBA 8(a) Certified
Quotes
(0)

Spo2 Simulator

Back to Product OxSim

Products

OxSim - SpO2 Pulse Oximetry Tester

Product Code : 02

The Netech Pulse OxSim SpO2 Oximetry Tester is the perfect complement to the SimCube family. It optically tests the entire system, including the sensor. Pocket sized, the OxSim runs on one AA alkaline battery for 10 hours. Test 4 Oxygen saturations, 3 pulse rates and a low perfusion mode all at the touch of a button. An indispensable tool for any biomed, OxSim fits in the SimCube carrying case and can be run simultaneously off the same battery boost option as your SimCube.

Show More... Add to cart

    Toggles between modes with different saturation values, different heart rates, and different perfusion levels using sigle button
    Automatically detects most different brands of oximeter probes; manually toggle through R-curves for others
    No complicated software menu to navigate
    Compact design - small enough to fit in your shirt pocket
    Provides 8 hours of continuous simulation time on a single AA battery
    Optical simulation with no need for adapter cables - tests the entire system, including the sensor
    Extremely rugged 

     

    Simulation Accuracy

    Saturation Error: Error in the displayed saturation value should be less than or equal to the specified error of the sensor which is typically +/- 2%, but which can be +/-3% or more for some disposable sensors.
    Heart Rate Error: Less than 1 bpm

    Modes of Operation

    85%: Saturation 85%; Pulse Rate 80 bpm ; Perfusion Index 2.0
    95%: Saturation 95%; Pulse Rate 40 bpm; Perfusion Index 2.0
    98%: Saturation 98%;  Pulse Rate 80 bpm; Perfusion Index 2.0
    140 BPM: Saturation 98%; Pulse Rate 140 bpm; Perfusion Index 2.0
    Low Perfusion: Saturation 99%; Pulse Rate 80 bpm; Perfusion Index 0.2

    Sensor Type Selection

    Nell/Mas Used for: All Nellcor, Masimo, Datascope, Protocol, Spacelabs, HP/Philips (blue extension cable), HP/Philips (tan soft sensor), Nihon Kohden, Colin, GE/Marquette, Welch Allyn
    HP/Ohm Used for: HP cocoa brown soft sensor, Ohmeda and Novametrix

    General

    Size: 2.5'' x 2.5'' x 1.25'' 
    Weight: 5 ounces (141.75 g) excluding battery
    SPO2 Connection: Optical
    Power Battery: 1 AA battery 
    Power Battery Life (Alkaline): 8 to 10 hours of simulation time (typical, depending on the oximeters under test); 60 days in sleep mode (unit sleeps after 10 min. with no probe connection)
    AC Operation: Included 6V DC supply operates over 100-240 VAC, 50-60 Hz

     

Download Brochure
Brochure not available...
Download Manual
Manual not available...
Part Number Description Price
OX-1 Optical SPO2 Simulator Add to cart