Back to Product MiniSim 1000 - ECG Arrhythmia Simulator

Products

ECG Arrhythmia Simulator

Product Code : MiniSim 1000 ECG, Arrhythmia waveform Simulator

 MiniSim-1000 Arrhythmia Simulator is a powerful yet basic patient simulator in a compact case. It is designed for testing the performance of all ECG monitoring instrumentation quickly and easily. 300his comprehensive microprocessor based instrument is menu driven using the  tactile feel keypad and easy-to-follow LCD display.

The MiniSim-12 provides full 12 lead ECG simulation with 14 user selectabel rates ranging from 30 to 350 BPM, and 14 user selectable amplitudes from 0.15 to 5 mV. The performance waveform includes Sine, Square and Triangle . 14 user-selectable waveform rates from 0.1 to 100 Hz and amplitudes from 0.15 millivolt to 5 millivolt.

The instrument is also designed to simulate 45 different arrhythmias including atrial, ventricular, tall T wave, ST elevation, ST depression, myocardial infraction, blocks, pulse and pacer waveforms.

 MiniSim 1000 Arrhythmia Dimulater is software upgradable to MiniSim 1000 full funcrion patient simulator including Blood pressure, respiration and temperature (YSI 400/YSI 700 compatable) 

 

Show More... Add to cart

    • Best Value
    • Easy to Use
    • Compact Size
    • Menu Driven operatoin
    • Large LCD Display
    • Tactile Keypad
    • Battery or AC Operation

     

    ECG: 12 leads with independent outputs referenced to RL
    NORMAL SINUS RHYTHM (NSR)
    ECG Rates: 30, 60, 70, 80, 90, 100, 120, 150, 180, 210, 240, 270, 300, and 350 BPM. Accuracy 0.5%.
    Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II. Lead 1 is 0.6 X Lead II, Lead III is 0.4 X Lead II, and Lead V is the same as Lead II.
    High Level: 500 X low level output on Lead II.
    Accuracy: 2% (1-5mV).

    PERFORMANCE WAVEFORMS (PERF)

    Sine, Square, Triangle, Pulse
    Frequencies: 0.1 to 0.9 in 0.1 Hz steps.1.0 to 9.0 in 1.0 Hz steps.10 to 100 in 10 Hz steps.
    Accuracy: 1%
    Amplitudes: 0.1, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV on Lead II.
    Pulse: 20 ms pulse of 1mV amplitude repeated at 4 second intervals.

    R WAVE DETECTION (RWD)

    Widths: 10, 40, 50, 60, 70, 80, 90, 100, 110, and 120 ms.
    Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mV on Lead II
    PACER (PCR)
    AP: Atrial Pacer set at 70 BPM
    ASP: Asynchronous Pacer- Ineffective Pacing
    QRS Amplitudes: 1 mV
    PCR: Pacer pulses alone
    Pacer Widths: 0.1, 0.2, 0.5, 1.0, 1.5, and 2.0 ms
    Amplitudes: 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mV
    VP: Ventricular Pacer set at 70 BPM
    AVP: Atrial Ventricular Pacer set at 70 BPM
    QRS Amplitude: 1 mV.Pacer Amplitude: -2mV

     